Alderlea T5 Instrukcje Operacyjne

Przeglądaj online lub pobierz Instrukcje Operacyjne dla Piece Alderlea T5. Alderlea T5 Operating instructions [en] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
150714-24 ALT5.ASCINSB 5055.203-BAS
MODEL: ALT5 INSERT
SERIES - D
Alderlea T5 Insert,
T5 Classic Insert
IMPORTANT:
KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
INSTALLATION AND OPERATING
INSTRUCTIONS
SAFETY NOTICE
If this stove is not properly installed, a house  re may result. For your safety,
follow the installation instructions. Contact local building or  re officials about
restrictions and installation inspection requirements in your area.
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD. - 2014
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - T5 Classic Insert

150714-24 ALT5.ASCINSB 5055.203-BASMODEL: ALT

Strona 2 - Contents

10ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD. 746mm 1.08m 772mm 1.08m 841mm 867mm 241mm 854mm 606mm 270mm 448mm 530mm 4

Strona 3 - Maintenance Checks

11ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.InstallationWarning: Under no circumstances is this heater to be installed in a makeshi

Strona 4 - Maintenance

12ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.be removed from the smoke shelf and adjacent damper frame if necessary to accommodate

Strona 5 - Creosote

13ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.Chimney and ConnectorWARNING: INSTALL CHIMNEY AND ALL COMPONENTS OF CHIMNEY SYSTEM ACCO

Strona 6 - Operation

14ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.O/A Cover ScrewO/A CoverFig. # 5Fig. # 6Fig. # 7two ways:1) Outside air (O/A) supply:

Strona 7

15ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.2) Remove Top(A) and Shields(B). (Fig. #8)3) Remove Surround Top and Sides from Pack

Strona 8 - Clearances

16ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.2) Disconnect fan wires as shown in Fig #16 from appropriate fan that is being replac

Strona 9

17ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.5) Loosen the screws on the wire support tabs and turn to remove the wires (Fig #23).6

Strona 10 - Dimensions

18ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.is important to prevent damage to wires.Surround Assembly and Installation1) Remove c

Strona 11 - Installation

2019ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.ITEM DESCRIPTION PART NO. 1...Regular Surround ...

Strona 12 - Full Flue Liner

2ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.ContentsMaintenance Checks...

Strona 13 - Installation Procedure

20ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.20ITEM DESCRIPTION PART NO. 1...Surround, Black Enamel...

Strona 14 - Remove Knockout

21ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.21TroubleshootingProblem Cause CureExcessive Creosote 1) Wood is too wet - Use dry

Strona 15

22ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.ITEM SIZE PART NUMBER N. America A 230 mm x 115 mm x 32 mm 5096.99 B 184 m

Strona 16 - Fan Removal/Installation

23ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.Label050914 5050.44ASModel: ALDERLEA T5Series: D Type: FIREPLACE INSERT

Strona 17 - FAN SHIELD

©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.PACIFIC ENERGY FIREPLACE PRODUCTS LTD.www.paci cenergy.netTechnical Support: 1-250-748-11842975 Allenby Rd., D

Strona 18

3ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.Check the following parts for damage such as cracks, excessive corrosion, burned out sec

Strona 19 - *NOT SHOWN

4ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.Maintenance1. Burn wood only, dry and well seasoned. The denser or heavier the wood w

Strona 20

5ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.In Case of a Chimney Fire1. Prepare to evacuate to ensure everyone’s safety. Have a we

Strona 21 - Troubleshooting

6ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.OperationWood SelectionThis heater is designed to burn natural wood only. Higher effic

Strona 22 - Firebrick Installation

7ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.BlowerThe Alderlea Insert comes equipped with twin variable speed circulating air blower

Strona 23 - MADE IN CANADA

300mm600mm300mm51mmAdjacent Wall8ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.SafetyPlease read this entire manual before installatio

Strona 24 - Printed in Canada

9ALT5.ASCINSB 150714-24©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.400mmNon-combustible  replace hearth622mm533mm457mm200mm200mmFireplace hearth requireme

Komentarze do niniejszej Instrukcji

Brak uwag